Skip to content

MOUNTING & LAYOUT · LAYOUT EXAMPLE

L-Foot Spacing for a 16-Foot Solar Mounting Rail

This five-L-foot layout example uses four 45-inch centre-to-centre spans and a 6-inch overhang at each rail end. Use the diagram and marking positions below alongside the mounting system’s project-specific limits.

See marking positions

Rail length16′ 0″ · 192″
Between L-foot centres3′ 9″ · 45″
Overhang at each end6″

Example L-Foot Spacing and Rail Overhang Diagram

The same layout adapts to your screen. Dimensions update with the feet/inches or millimetres selector below.

L-foot spacing example for a 16-foot solar mounting railFive support centres on a 192-inch rail: 6, 51, 96, 141 and 186 inches from the same end. Four spans of 45 inches; 6-inch overhang at each end. Layout example; verify the rail system and site design before use.SIDE ELEVATION · SUPPORT CENTRES45″45″45″45″6″6″L1L2L3L4L5192″OVERALL RAIL LENGTHL-foot spacing example for a 16-foot solar mounting railFive support centres on a 192-inch rail: 6, 51, 96, 141 and 186 inches from the same end. Four spans of 45 inches; 6-inch overhang at each end. Rail orientation is rotated to fit a phone. Layout example; verify the rail system and site design before use.SAME LAYOUT · ROTATED FOR MOBILEL1L2L3L4L545″45″45″45″6″6″192″OVERALL RAIL LENGTH
Responsive SVG · dimensions drawn to scale along the rail. View full-size SVG (inches) ↗Download SVG diagram (inches) ↓

QUICK REFERENCE

L-Foot Centre-Line Marking Positions

Start at one end of the rail. These are the positions of the L-foot centre lines, not the edges of the feet.

Five support centres measured from the starting end of a 192-inch rail
SupportPosition from starting end
L16″
L24′ 3″ · 51″
L38′ 0″ · 96″
L411′ 9″ · 141″
L515′ 6″ · 186″

6″ + (4 × 45″) + 6″ = 192″

Confirm the actual rail length before marking. This example is exactly 16′ 0″; a rail supplied at a different length needs its layout checked.

BEFORE FIXING

Checks Before Installing Solar Mounting Rails

  1. Rail and attachment limits. Check the allowed span, end overhang, fastener requirements and splice restrictions for the specific mounting system.
  2. Supporting structure. Fix into suitable structural members or an approved engineered attachment. Adjusting a foot to meet a fixing point changes the adjacent spans.
  3. Panel clamp positions. Check the module manufacturer’s clamp zones separately. L-foot support spacing does not establish the panel’s permitted clamping positions.

Sources and Applicability of This Rail Layout

The dimensions above are redrawn from the HUMMN-supplied layout reference. The SVG uses proportional spacing; rotating the phone view does not change the dimensions. The layout arithmetic is 6 + 4 × 45 + 6 = 192 inches.

IronRidge: understanding rail span and cantilever ↗ explains these terms and the use of system-specific span tables. It is a general reference, not approval for this layout or for another manufacturer’s rail.

Updated 7 November 2026 · Example layout · Recheck against the installed equipment and site design.